Modulus Single Tube Fluorometer
The Concept The Modulus
Single Tube Fluorometer is designed to provide utmost flexibility. The
Modulus Single Tube operates as a dedicated fluorometer, or a combination
fluorometer/luminometer. With the optional Absorbance Module, absorbance
measurements are available in the visible wavelength spectrum. Modulus
allows you to buy what you need now, and to add what you want later. Fluorescent
measurements with the Modulus are simple. Several optical kits are available
for the most common fluorescent applications. The optics are factory installed
into an Optical Kit that snaps into the Modulus. Each kit contains a light
source, an excitation filter, and an emission filter to yield the highest
performance.
Nucleic Acid Quantitation The Modulus provides high sensitivity for fluorescent measurements of DNA and RNA. There are two options for measuring nucleic acids on the Modulus. Quantitate DNA via PicoGreen or Hoechst or quantitate RNA via RiboGreen or Quant-iT RNA. You can detect as little as 4.5 pg of dsDNA in 100 ul using PicoGreen and the Minicell Adaptor. Use the Minicell Adaptor to minimize reagent volume and cost. Protein Quantitation The Modulus provides flexibility for protein measurement. The two methods for measuring proteins on the Modulus are fluorescence or absorbance. Quantiate protein via Quant-iT Protein Assay using a Fluorescence Optical Kit. Alternatively, the Bradford, Lowry, and BCA assays are possible with the Absorbance Module. Gene Expression The Modulus provides flexibility for gene expression measurements. The two methods for measuring gene expression on the Modulus are fluorescence or luminescence. As a fluorometer, the Modulus is capable of measuring several different GFP variants. Luminescence The Luminescence Module accommodates luminescent assays such as ATP measurements, gene expression using luciferase, or other bio- and chemiluminescent measurements. Change the module to switch between fluorescence and luminescence. Gene Expression The Modulus provides flexibility for gene expression measurements. The two methods for measuring gene expression on the Modulus are fluorescence or luminescence. As a luminometer, the Modulus analyzes luciferase expression coupled to gene expression. ATP Measurements and Reactive Oxygen Species (ROS) The Modulus
as a luminometer measures cell viability through the use of ATP determination.
Cell viability can also be measured using the ATP-dependent oxidation
of luciferase. ROS assays that utilize chemiluminescent substrates such
as luminol can also be measured on the Modulus. Protein Quantitation The Modulus provides flexibility for protein measurement. The two methods for measuring proteins on the Modulus are fluorescence or absorbance. The Bradford, Lowry, and BCA assays are possible with the Absorbance Module. Modulus Single Tube General Specifications General
Specifications Modulus Fluorometer Specifications Fluorescence
Module Performance For research use only. Not for use in diagnostic procedures.
|
|
|