![]() |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
|
"I just received our brand new Modulus. It only takes 15 minutes to set it up and it is extremely easy for us to use. I invited everyone in the company to see and use the Modulus. Turner’s engineering is something I can expect the best and I am always impressed with. I have evaluated most of your luminometers and I have now two (20/20n and Modulus) in my lab." E-mail from customer who purchased the Modulus Microplate instrument "I received the Modulus. It is so easy to set up and program the instrument, I did it in 15 minutes. My interns tested absorbance module at 450 nm and it read wonderful. All the parts are working well. We will evaluate luminometer and absorbance modules in the next two weeks. I was very impressed with the system."
|
Modulus™ Microplate Multimode Reader Product Series: Multimode Plate Readers For a limited time, order a Modulus Microplate Multimode Reader and receive a free 4GB iPod nano! In addition to playing music and videos, the iPod can be used to transfer data between your Modulus and your computer. [View Promotion Terms] [Request a Quotation] Overview The Modulus™ Microplate Multimode Reader is skillfully designed for today’s life science laboratory. In addition to having performance on par with single-mode instruments, the Modulus™ Microplate blends user-friendly operation with easy data handling and flexible purchasing options. The result of this design is an instrument with superior performance that is easy to use, is affordable, and can be customized to your laboratory’s needs.
The Modulus™ Microplate Multimode Reader combines the superior performance expected from single-mode instruments with the functionality of multiple modes. To achieve industry-leading performance, the Modulus™ Microplate is designed with optical channels dedicated to each individual technology. Unlike other multimode systems, readings taken with the Modulus™ Microplate are not degraded by indirect fiber-optic transmission or crowded optical channels. Dedicated optical channeling ensures that the Modulus™ Microplate provides sensitivity and dynamic range on par with the highest performing single-mode instruments.
The Modulus™ Microplate Multimode Reader is designed to be put into use straight from the box, without the need to read a manual or obtain special training. To achieve this plug-and-play usability, the Modulus™ Microplate combines a color LCD touch screen with a Windows-based onboard computer. The built-in computer eliminates the connectivity hassles, cost, and space requirements of running an external computer. Assay set-up on the Modulus™ Microplate is effortless with several flexible set-up options to choose from. Once an assay is run, data can be transferred in Excel-compatible .csv format from the Modulus™ Microplate using the built-in USB drive and the USB stick that comes with the instrument. The Modulus™ Microplate is a modular instrument that easily fits into most budgets. Purchase the technology or modes that you need now and add onto the system later as your needs expand. For example, the Modulus™ Microplate can be purchased as a luminometer, then fluorescence and/or absorbance modules can be purchased and added later.
Figure 1: The Luminescence Module light path is isolated through a dual-masking system at both the detector and at the well being read. The dual-masking system is designed to eliminate stray light by creating a column through which the light from the sample passes to the detector.
Figure 2: The Fluorescence Module uses an epifluorescent design to ensure a consistent measurement position. This approach reduces the impact of small sample volume fluctuations by consistently measuring the sample at the same position from well to well.
Figure 3: The Absorbance Module comes with four factory-installed filters for measuring ELISA and protein quantitation assays. In addition, custom filters can be easily added to the two removable filter paddles for expanded assay options. Luminescence Channel • > 8 logs dynamic range
*Recommended
The Modulus™ Microplate Multimode Reader with the Luminescence Module is designed to deliver performance equivalent to dedicated microplate luminometers while also offering the flexibility of a multimode reader. To achieve sensitivity on par with that of a dedicated luminometer, the luminescence channel is separated from other measurement technologies and positioned directly above the sample well. These conditions maximize light capture for the best possible sensitivity. In conjunction, a low-noise photomultiplier tube ensures that collected light is not compromised in any way. This design makes the Modulus™ Microplate between 10 to 1000 times more sensitive than competing multimode luminometers. In addition to high sensitivity, the Modulus™ Microplate boasts greater than 8 logs of dynamic range, eliminating the need to dilute samples or manage detector-driven gain changes. To achieve this extra large reading range, the Modulus™ Microplate is capable of simultaneously measuring samples of varying brightness. The photomultiplier tube automatically adjusts for the optimum reading of bright or dim samples. This means that the Modulus™ Microplate is capable of achieving a reading range of 2 – 3 logs more than competing multimode luminometers. For further functionality, a Modulus™ Microplate with the Luminescence Module is designed to reduce crosstalk. The luminescent light path is isolated through a dual-masking system at both the detector and the well being read. Dual masking eliminates stray light by creating a column in which the light from the sample passes directly to the detector. When using 96-well white plates, this dual-masking system effectively results in a crosstalk rejection of 5 x 10-5. Fluoresence Channel • Epifluorescent detection
A Modulus™ Microplate Multimode Reader with the Fluorescence Module installed is designed to deliver both high performance and user flexibility. To achieve high performance, the Fluorescence Module utilizes powerful light-emitting diodes (LEDs) as excitation sources. LEDs have very specific light-output profiles which closely match the excitation profiles of commonly used fluorescent molecules. LED usage increases sensitivity by fully exciting the fluorophore and reducing non-specific light leakage, a problem often found when using broad-spectrum light sources. Additionally, the Modulus™ Microplate Fluorescence Module uses an epifluorescent design to ensure a consistent measurement position. This pinpointed approach reduces the impact of volume fluctuation within small samples by reliably measuring at the same position from well to well. The Modulus™ Microplate Fluorescence Module accepts different Fluorescence Optical Kits for measuring a variety of fluorophores. Four standard optical kits are available to measure the most popular fluorophores including Hoechst dye, fluorescein, rhodamine, Cy3, and Cy5. In addition, custom optical kits can be readily made for non-standard applications. Optical kits can be easily exchanged in seconds and built-in software ensures that the installed optical kit matches the selected application protocol. Protocols for nucleic acids and proteins such as PicoGreen®, RiboGreen®, and Quant-iT™ assays are preprogrammed into the Modulus™ Microplate for your convenience. The Modulus™ Microplate Fluorescence Module is designed as a user-installable module. This means that you can either buy the Fluorescence Module now or add it to your system later when your lab is ready to run fluorescence experiments. The ability to add modules as you need them gives you great purchasing flexibility. Installation is easy and takes less than ten minutes with the provided tool. There is no downtime or need for a service call. Absorbance Channel • Flexible filter system
Absorbance Module (400 - 800 nm) (User Installable) The Modulus™ Microplate Multimode Reader with Absorbance Module provides measurements that are highly sensitive and cover a wide dynamic range. The absorbance channel has a reading range of 0 - 5.0 Optical Density (OD) with an accuracy that deviates less than 2%. The channel consists of a white LED with a spectral range of 400 to 800 nm positioned at the bottom of the instrument. As it shines through the bottom of the plate, your sample absorbs the light in a wavelength range that is dictated by your individual application. The final stage for measuring absorbance involves the light passing into a large-area photodiode where it is measured and processed. The Absorbance Module comes with two open filter slots and four factory-installed filters. The preinstalled filters are for 450, 560, 600, and 750 nm as these cover the most common ELISA and protein assays. With two open filter slots, you can also customize the absorbance module by adding the filter paddle of your choice. In addition, it is easy to run ratiometric absorbance-based assays to adjust for optical imperfections. Simply use the color touch screen to select the two desired wavelengths. OD values for each wavelength or a ratio of the two wavelengths will appear on the easy-to-read display screen. Intuitive User Interface The Windows-based computer built into the Modulus™ Microplate Reader offers dynamic user-interface capabilities. Simply choose from three options on the instrument touch screen to start setting up a run.
Injectors Both single and dual injectors are available for the Modulus™ Microplate Luminometer. Each injector has a volume range of 25 – 200 µl in 5-µl increments. Installed injector systems are automatically recognized by the instrument and controlled using the touch screen and fluidics wizard. Prime and Flush commands provide easy maintenance and a Reverse Purge command saves valuable reagents. Injectors are recommended for labs running experiments with flash-based luminescence applications or dual-reporter assays. Luminescence Light Plate
Microplate Format Data Analysis Computer Interface Modulus™ Microplate Multimode Reader Detection Modes: Luminescence, Fluorescence, Absorbance Luminescence Module Specifications (9300-020 Factory Installed) Detector: Head-on photomultiplier tube (PMT) for photon counting Fluorescence Module Specifications (9300-040 User Installable) Light Source: Wavelength-matched LED Absorbance Module - Vis Specifications (9300-050 User Installable) Light Source: LED Single Injector System Specifications (9300-061 Optional) Number of Injectors: One injector Dual Injector System Specifications (9300-062 Optional) Number of Injectors: Two injectors
For research use only. Not for use in diagnostic procedures. Modulus is a trademark of Turner BioSystems, Inc. All other trademarks are the sole property of their respective owners. Terms of iPod Promotion: |
| |||||||||||||||||||||||||||||||||||||||||||||||
|